10.3. Motor Sizes According to IEC

Standardization of motor frame sizes creates the advantage that there are only a limited number of different flange dimensions and shaft diameters. IEC 60072 standardizes motor frame sizes for regions that use SI units. Regions that use imperial units work with NEMA standards (see next chapter Motor Designs).
Common IEC frame sizes are shown with example performance data (IE4) in the table below. The size number indicates the height of the center axis of the motor.

Size Number of poles Power (output) [kW] Speed [1/min] Flage [mm] Bore circle [mm] Bore [mm] Shaft diameter [mm]
63 4 0,18 1500  140  115  9  11
71 4 0,37 1500  160  130  10  14
80 4 0,75 1500  200  165  12  19
90 4 1,5 1500  200  165  12  24
100 4 3 1500  250  215  14  28
112 6 4 1500  250  215  14  28
132 6 75 1500  300  265  14  38
160 6 15 1500  350  300  19  42
180 8 22 1500  350  300  19  48
200 8 30 1500  400  350  19  55

 